Q: I’m an architect who has also done my fair share of swinging a hammer. Recently, you recommended fastening shear ply with screws. The California Building Code and other U.S. building codes have always had schedules for shear wall nailing (although they do permit other types of fasteners).

My structural engineers have always said that the shear value of nails is far better than the shear value of screws. The screws are far more brittle. This has been borne out in my own construction, where screws have snapped off while being driven.

Q: I’m an architect who has also done my fair share of swinging a hammer. Recently, you recommended fastening shear ply with screws. The California Building Code and other U.S. building codes have always had schedules for shear wall nailing (although they do permit other types of fasteners).

My structural engineers have always said that the shear value of nails is far better than the shear value of screws. The screws are far more brittle. This has been borne out in my own construction, where screws have snapped off while being driven.

Because the person writing is in a high-risk seismic area, you were right to recommend plywood and to fasten it to the bottom plate. But he also needs to have the best fasteners for the job: nails.

A: You reference a recent column where a reader asked for clarification about diagonal bracing ("Don’t expect miracle from diagonal bracing," Dec. 28, 2011). He lives in a high-risk seismic zone. We explained how the bracing is constructed but suggested that for a better job he consider installing structural plywood shear panels instead.

Although we proposed screws as alternative fasteners, we agree that nailing the panels according to a code-specified nailing schedule is the tried-and-true method.

Shear panels refer to structural panels that make up exterior walls. They provide protection from the lateral forces of earthquakes. They are normally constructed by nailing 1/2-inch plywood to all framing members running from the mudsill (the piece of wood bolted to the foundation) to the top plate.

Plywood can be placed either horizontally or vertically and must be nailed on all edges and in the field to framing members. This creates a rigid diaphragm. If an edge falls in the middle of a stud bay, blocking must be installed to provide a complete nailing surface.

Our reader wanted to provide protection from the inside. To accomplish this, 1/2-inch plywood is installed vertically and nailed to all studs, the top plate and bottom plate. Understand that this only provides partial protection.

It will eliminate cracks in the plaster or visible seams in drywall, but because it doesn’t tie the mudsill and cripple wall (which are below floor level) to the stud wall, lateral forces in an earthquake may cause the building to move.

There are a couple of other things to consider while the studs are exposed. Whether the job is attacked from the inside or from the outside, this is a great time to insulate and inspect and upgrade the electrical wiring.

We consulted a cousin, Dan Smith, who is a retired master electrician. He recommended that if the wiring in the wall is ungrounded knob and tube or old sheathed cable, consider replacing it. It’s quite possible that the insulation around the wires has deteriorated, creating a hazard.

If the wiring is grounded three-wire Romex, you can add outlets or lights provided that the circuit is not already maxed out. Dan’s rule of thumb for a 15-amp circuit serving living areas (not kitchens or other high-load areas) is 10 outlets.

This assumes a normal electrical load and provides a little "fudge factor" if the homeowner occasionally plugs in an appliance with a heavier draw.

Of course, as always, get a permit and have the work inspected whether you do it or hire it out.

Insulation is pretty straightforward. If there is none, add it. Consider using spray-foam insulation if it’s not too costly, or use faced insulation batts and turn the kraft paper vapor barrier toward the home’s interior. In either case, insulate after the new electrical work is completed.

If replacing interior lath-and-plaster walls, we suggest using unfaced batt insulation and a vapor barrier of plastic sheeting, known as Visqueen. Seal all cuts and seams in the plastic with the appropriate tape. Install the sheeting and then the drywall, tape, texture and paint.

Show Comments Hide Comments
Sign up for Inman’s Morning Headlines
What you need to know to start your day with all the latest industry developments
By submitting your email address, you agree to receive marketing emails from Inman.
Success!
Thank you for subscribing to Morning Headlines.
Back to top
×
Log in
If you created your account with Google or Facebook
Don't have an account?
Forgot your password?
No Problem

Simply enter the email address you used to create your account and click "Reset Password". You will receive additional instructions via email.

Forgot your username? If so please contact customer support at (510) 658-9252

Password Reset Confirmation

Password Reset Instructions have been sent to

Subscribe to The Weekender
Get the week's leading headlines delivered straight to your inbox.
Top headlines from around the real estate industry. Breaking news as it happens.
15 stories covering tech, special reports, video and opinion.
Unique features from hacker profiles to portal watch and video interviews.
Unique features from hacker profiles to portal watch and video interviews.
It looks like you’re already a Select Member!
To subscribe to exclusive newsletters, visit your email preferences in the account settings.
Up-to-the-minute news and interviews in your inbox, ticket discounts for Inman events and more
1-Step CheckoutPay with a credit card
By continuing, you agree to Inman’s Terms of Use and Privacy Policy.

You will be charged . Your subscription will automatically renew for on . For more details on our payment terms and how to cancel, click here.

Interested in a group subscription?
Finish setting up your subscription
×